Power Metering and Measurement
Watt-Hour Uncertainty Calculator
Estimate combined expanded measurement uncertainty in watt-hours from power and time measurement tolerances.
Step-by-step working▼
- E = 250 W × 4 h = 1,000 Wh
- u(rel) = √(0.5² + 0.1²) = 0.51%
- U(rel) = 2 × 0.51% = 1.02%
- U = 1,000 × 1.02% = ±10.198 Wh
What Is the Watt-Hour Uncertainty Calculator?
A Watt-Hour Uncertainty Calculator is a tool that combines the uncertainty of a power measurement and a time measurement into the expanded uncertainty of an energy result in watt-hours (Wh).
Energy is power × time, so its relative uncertainty is the root-sum-square of the relative uncertainties of power and time. 250 W ±0.5% for 4 hours ±0.1% gives 1,000 Wh with a combined relative uncertainty of 0.51%. With a coverage factor k = 2 (about 95% confidence), the result is 1,000 Wh ±10.2 Wh.
The calculator returns expanded uncertainty in Wh, the measured energy, the combined relative uncertainty and the expanded relative uncertainty.
How Does the Watt-Hour Uncertainty Calculator Work?
The Watt-Hour Uncertainty Calculator works by squaring the 2 relative uncertainties, adding them, taking the square root and multiplying by the coverage factor and the energy.
- Enter the power and its uncertainty: Type the watts and the meter uncertainty in percent.
- Enter the time and its uncertainty: Type the hours and the timing uncertainty in percent.
- Pick the coverage factor: Choose k = 1, 2 or 3 for about 68%, 95% or 99.7% confidence.
- Read the uncertainty: The tool shows the result as Wh ± U.
Watt-Hour Uncertainty Calculator Formula
The Watt-Hour Uncertainty formula is U = k × E × √(u(P)² + u(t)²), with u values as relative uncertainties.
U = k × E × √(uP² + ut²)
E = P × tu(rel) = √(uP² + ut²)U(rel) = k × u(rel)
| Symbol | Meaning |
|---|---|
U | Expanded uncertainty in Wh |
k | Coverage factor |
E | Measured energy |
uP | Relative uncertainty of power |
ut | Relative uncertainty of time |
Watt-Hour Uncertainty Calculator Example
A power analyzer reads 1,200 W ±0.2% for 0.5 h measured with a stopwatch to ±0.5%.
- E = 1,200 × 0.5 = 600 Wh
- u(rel) = √(0.2² + 0.5²) = 0.539%
- U = 2 × 0.539% × 600 = ±6.5 Wh
The energy is 600 Wh ±6.5 Wh at k = 2. The stopwatch dominates the uncertainty.
Watt-Hour Uncertainty Calculator Conversion Table
The table shows 6 pairs of power and time uncertainty.
| Power uncertainty | Time uncertainty | Combined (k = 1) | Expanded (k = 2) | Expanded (Wh) |
|---|---|---|---|---|
| 0.1% | 0.01% | 0.100% | 0.201% | ±2.0 |
| 0.5% | 0.1% | 0.510% | 1.020% | ±10.2 |
| 1% | 0.1% | 1.005% | 2.010% | ±20.1 |
| 1% | 1% | 1.414% | 2.828% | ±28.3 |
| 2% | 0.5% | 2.062% | 4.123% | ±41.2 |
| 3% | 1% | 3.162% | 6.325% | ±63.2 |
The larger uncertainty dominates. Improving the smaller one changes little.
What Are the Uses of the Watt-Hour Uncertainty Calculator?
The Watt-Hour Uncertainty Calculator has 4 main uses: lab reports, test planning, product claims and calibration work.
- Lab reports: State energy results with an uncertainty, as required by ISO/IEC 17025.
- Test planning: Find which instrument limits accuracy.
- Product claims: Support battery capacity claims with an uncertainty budget.
- Calibration work: Combine instrument uncertainties for energy tests.
Watt-Hour Uncertainty Calculator FAQ
What is expanded uncertainty?▼
Expanded uncertainty is the combined uncertainty multiplied by a coverage factor k, giving a range with a set confidence.
Why add uncertainties as squares?▼
Independent random errors combine by root-sum-square, following the Guide to the Expression of Uncertainty in Measurement (GUM).
What coverage factor should I use?▼
Use k = 2 for about 95% confidence, the common choice in reports.
Related Power Metering and Measurement Tools
Power Log to Watt-Hours Calculator
Integrate recorded power readings over interval steps to calculate cumulative energy in watt-hours.
Cable Energy Loss Calculator
Calculate resistive energy losses in watt-hours dissipated through electrical wiring over an operating period.
Energy Meter Reading Calculator
Calculate kilowatt-hours and watt-hours consumed between successive utility meter reading dates.
Meter Pulse to Watt-Hours Calculator
Convert counted optical meter pulses into consumed energy in watt-hours using the meter pulse constant.
Energy Meter Multiplier Calculator
Apply instrument transformer metering multipliers to commercial electric meter registers.
Energy Measurement Error Calculator
Compare measured energy values with a calibrated reference standard to compute percentage measurement error.