Calculate alternating-current energy in watt-hours including power factor and operating duration.

AC Watt-Hour Calculator InputsWh = V × A × PF × h
V
A
hours
Result
Real energy
4,968Wh
Kilowatt-Hours (kWh)
4.968kWh
Real power828 W
Apparent power920 VA
Reactive energy2,406.11 VArh
Step-by-step working▼
  1. S = V × I = 230 V × 4 A = 920 VA
  2. P = S × PF = 920 VA × 0.9 = 828 W
  3. Wh = P × t = 828 W × 6 h = 4,968 Wh
  4. VArh = S × √(1 − PF²) × t = 2,406.1122 VArh

What Is the AC Watt-Hour Calculator?

An AC Watt-Hour Calculator is a tool that calculates real energy in watt-hours (Wh) for alternating-current (AC) loads from RMS voltage, RMS current, power factor (PF) and time.

In an AC circuit, volts × amps gives apparent power in volt-amperes (VA), not real power. Motors, compressors and switch-mode power supplies shift current out of phase with voltage. The power factor, a number from 0 to 1, tells how much of the VA does real work.

The calculator returns 5 values: real energy (Wh), real power (W), apparent power (VA), reactive energy (VArh) and kilowatt-hours (kWh). A 230 V load drawing 4 A at PF 0.9 for 6 hours uses 4,968 Wh of real energy.

How Does the AC Watt-Hour Calculator Work?

The AC Watt-Hour Calculator works by multiplying voltage by current to get VA, multiplying VA by the power factor to get watts, and multiplying watts by hours to get watt-hours.

  1. Enter the RMS voltage: Type the supply voltage, such as 120 V, 230 V or 240 V.
  2. Enter the RMS current: Type the current from a clamp meter or the nameplate.
  3. Set the power factor: Use 1.0 for heaters and incandescent lamps, 0.8–0.9 for motors and 0.5–0.7 for small electronics without PF correction.
  4. Enter the time: Type the hours of operation and read Wh, W, VA and VArh.

AC Watt-Hour Calculator Formula

The AC Watt-Hour formula is Wh = V × A × PF × h.

Wh = V × A × PF × h

  • VA = V × A
  • W = VA × PF
  • VArh = VA × √(1 − PF²) × h
Variables in the AC Watt-Hour Calculator formula
SymbolMeaning
VRMS voltage
ARMS current
PFPower factor (0 to 1)
hTime in hours
VArhReactive energy in volt-ampere reactive hours

AC Watt-Hour Calculator Example

A 120 V pool pump draws 8 A at PF 0.85 for 6 hours.

  1. VA = 120 V × 8 A = 960 VA
  2. W = 960 × 0.85 = 816 W
  3. Wh = 816 W × 6 h = 4,896 Wh

The pump uses 4,896 Wh (4.9 kWh) of real energy.

AC Watt-Hour Calculator Conversion Table

The table shows how the power factor changes real energy for 6 AC loads at 230 V over 1 hour.

AC real energy for 1 hour at 230 V
Load typeCurrent (A)Power factorApparent power (VA)Real energy (Wh)
Kettle8.71.02,0012,001
Fridge compressor1.20.75276207
Washing machine motor2.50.8575460
LED driver (no PFC)0.10.552312.7
Desktop PC (with PFC)1.10.98253248
Air conditioner6.00.91,3801,242

Utility meters for homes bill real energy (Wh and kWh). Some commercial tariffs charge for reactive energy as well.

What Are the Uses of the AC Watt-Hour Calculator?

The AC Watt-Hour Calculator has 4 main uses: motor energy audits, generator sizing, power factor review and UPS planning.

  • Motor energy audits: Find the real kWh used by pumps, fans and compressors from clamp-meter readings.
  • Generator sizing: Compare VA with W to size a generator rated in kVA.
  • Power factor review: See the reactive energy a low-PF load adds to the supply.
  • UPS planning: Check that both the VA and W ratings of a UPS cover the connected load.

AC Watt-Hour Calculator FAQ

Why is AC energy lower than volts × amps × hours?▼

AC energy is lower when the power factor is below 1. Volts × amps gives apparent power, and only the PF share does real work.

What power factor should I use if I do not know it?▼

Use 1.0 for resistive heaters, 0.85 for motors and 0.6 for small electronics without PF correction.

Does my electricity meter measure VA or W?▼

Residential meters measure real energy in Wh and kWh.