Power Metering and Measurement
Power Log to Watt-Hours Calculator
Integrate recorded power readings over interval steps to calculate cumulative energy in watt-hours.
Step-by-step working▼
- Interval 1: (120 + 180) ÷ 2 × 0.25 h = 37.5 Wh
- Interval 2: (180 + 450) ÷ 2 × 0.25 h = 78.75 Wh
- Interval 3: (450 + 430) ÷ 2 × 0.25 h = 110 Wh
- Interval 4: (430 + 200) ÷ 2 × 0.25 h = 78.75 Wh
- Interval 5: (200 + 150) ÷ 2 × 0.25 h = 43.75 Wh
- Interval 6: (150 + 140) ÷ 2 × 0.25 h = 36.25 Wh
- Total = 385 Wh over 1.5 h; average = 256.7 W
What Is the Power Log to Watt-Hours Calculator?
A Power Log to Watt-Hours Calculator is a tool that turns a series of power readings in watts (W), taken at a fixed interval, into total energy in watt-hours (Wh) using the trapezoidal rule.
Data loggers, smart plugs and inverter apps record power every few seconds or minutes. Energy is the area under that power curve. The trapezoidal rule averages each pair of neighbouring readings and multiplies by the interval. 7 readings of 120, 180, 450, 430, 200, 150 and 140 W at 15-minute intervals give 385 Wh over 1.5 hours, an average of 256.7 W.
The calculator returns energy in Wh, average power, peak reading and logged duration, with a bar for each reading.
How Does the Power Log to Watt-Hours Calculator Work?
The Power Log to Watt-Hours Calculator works by averaging each pair of neighbouring readings, multiplying by the interval in hours and adding all intervals.
- Paste the readings: Type or paste the watt readings in time order, separated by commas.
- Enter the interval: Type the minutes between readings, or pick 1, 15 or 60 minutes.
- Read the energy: The tool shows total Wh, average W, peak W and duration.
- Check the intervals: Open the working to see the energy of each interval.
Power Log to Watt-Hours Calculator Formula
The Power Log to Watt-Hours formula is Wh = Σ ((Pᵢ + Pᵢ₊₁) ÷ 2) × Δt, with Δt in hours.
Wh = Σ (Pᵢ + Pᵢ₊₁) ÷ 2 × Δt
Δt (h) = interval (min) ÷ 60P(avg) = Wh ÷ total hours
| Symbol | Meaning |
|---|---|
Pᵢ | Power reading i in watts |
Δt | Time between readings in hours |
Wh | Total energy |
Power Log to Watt-Hours Calculator Example
A heat pump logs 0, 2,400, 2,200 and 900 W at 1-hour intervals.
- Hour 1 = (0 + 2,400) ÷ 2 × 1 = 1,200 Wh
- Hour 2 = (2,400 + 2,200) ÷ 2 × 1 = 2,300 Wh
- Hour 3 = (2,200 + 900) ÷ 2 × 1 = 1,550 Wh
- Total = 5,050 Wh
The heat pump used 5,050 Wh (5.05 kWh) over 3 hours.
Power Log to Watt-Hours Calculator Conversion Table
The table shows each of the 6 intervals in the default log.
| Interval | Start reading (W) | End reading (W) | Average (W) | Energy (Wh) |
|---|---|---|---|---|
| 1 | 120 | 180 | 150 | 37.5 |
| 2 | 180 | 450 | 315 | 78.75 |
| 3 | 450 | 430 | 440 | 110 |
| 4 | 430 | 200 | 315 | 78.75 |
| 5 | 200 | 150 | 175 | 43.75 |
| 6 | 150 | 140 | 145 | 36.25 |
Total = 385 Wh. Shorter intervals capture fast load changes more accurately.
What Are the Uses of the Power Log to Watt-Hours Calculator?
The Power Log to Watt-Hours Calculator has 4 main uses: logger data analysis, appliance testing, solar output totals and demand studies.
- Logger data analysis: Turn a CSV column of watts into energy.
- Appliance testing: Measure the energy of one full appliance cycle.
- Solar output totals: Add up inverter power readings into daily Wh.
- Demand studies: Find the average and peak load from interval data.
Power Log to Watt-Hours Calculator FAQ
How do I convert power readings to energy?▼
Average each pair of readings, multiply by the interval in hours and add the results.
What is the trapezoidal rule?▼
The trapezoidal rule estimates the area under a curve by joining readings with straight lines.
What interval should a logger use?▼
Use 1 minute or less for cycling loads, and 15 minutes for whole-home or solar data.
Related Power Metering and Measurement Tools
Cable Energy Loss Calculator
Calculate resistive energy losses in watt-hours dissipated through electrical wiring over an operating period.
Energy Meter Reading Calculator
Calculate kilowatt-hours and watt-hours consumed between successive utility meter reading dates.
Meter Pulse to Watt-Hours Calculator
Convert counted optical meter pulses into consumed energy in watt-hours using the meter pulse constant.
Energy Meter Multiplier Calculator
Apply instrument transformer metering multipliers to commercial electric meter registers.
Energy Measurement Error Calculator
Compare measured energy values with a calibrated reference standard to compute percentage measurement error.
Watt-Hour Uncertainty Calculator
Estimate combined expanded measurement uncertainty in watt-hours from power and time measurement tolerances.