Skip to main content
Watt Hour Calculator logo
Watt Hour Calculator

Battery Sizing and Runtime

Usable Battery Energy Calculator

Calculate practical usable battery energy accounting for maximum depth of discharge and inverter loss.

Usable Battery Energy Calculator InputsWh(AC) = V × Ah × DoD × η
V
Ah
%
%
Result
Usable AC energy
1,036.8Wh
Nominal energy1,280 Wh
Usable DC energy1,152 Wh
Inverter loss115.2 Wh
Step-by-step working▼
  1. Nominal = 12.8 V × 100 Ah = 1,280 Wh
  2. Usable DC = 1,280 × 90% = 1,152 Wh
  3. Usable AC = 1,152 × 90% = 1,036.8 Wh

What Is the Usable Battery Energy Calculator?

A Usable Battery Energy Calculator is a tool that calculates how many watt-hours (Wh) a battery delivers to AC loads after depth of discharge (DoD) and inverter losses.

The label energy of a battery is not all available. Lead-acid batteries last longest when discharged to 50% DoD, and lithium batteries to 80–90%. An inverter then loses 5–15% converting direct current (DC) to alternating current (AC). A 12.8 V 100 Ah battery holds 1,280 Wh, but delivers about 1,037 Wh to AC loads.

The calculator returns usable AC energy, nominal energy, usable DC energy and the inverter loss, with a bar chart of all 3 energy levels.

How Does the Usable Battery Energy Calculator Work?

The Usable Battery Energy Calculator works by multiplying nominal Wh by the DoD to get usable DC energy, then by the inverter efficiency to get usable AC energy.

  1. Enter the voltage and capacity: Type the battery voltage and Ah rating.
  2. Set the depth of discharge: Use 50% for lead-acid, 80% for Li-ion and 90% for LiFePO4.
  3. Set the inverter efficiency: Use 85–95% from the inverter datasheet.
  4. Read the usable energy: The tool shows AC Wh, DC Wh, nominal Wh and the loss.

Usable Battery Energy Calculator Formula

The Usable Battery Energy formula is Wh(AC) = V × Ah × DoD × η(inverter).

Wh(AC) = V × Ah × DoD × η

  • Wh(DC) = V × Ah × DoD
  • Loss = Wh(DC) − Wh(AC)
Variables in the Usable Battery Energy Calculator formula
SymbolMeaning
VBattery voltage
AhBattery capacity
DoDDepth of discharge as a decimal
ηInverter efficiency as a decimal

Usable Battery Energy Calculator Example

A 12 V 200 Ah AGM battery feeds a 90% efficient inverter at 50% DoD.

  1. Nominal = 12 × 200 = 2,400 Wh
  2. DC usable = 2,400 × 0.5 = 1,200 Wh
  3. AC usable = 1,200 × 0.9 = 1,080 Wh

The battery delivers 1,080 Wh to AC loads.

Usable Battery Energy Calculator Conversion Table

The table shows how DoD and inverter efficiency cut a 1,200 Wh nominal rating.

Usable AC energy from a 1,200 Wh battery
ChemistryDoDDC usable (Wh)AC at 85% (Wh)AC at 92% (Wh)
Flooded lead-acid50%600510552
AGM50%600510552
Gel60%720612662
Li-ion NMC80%960816883
LiFePO490%1,080918994
LiFePO4 (full)100%1,2001,0201,104

Running LiFePO4 to 100% DoD every cycle shortens its cycle life.

What Are the Uses of the Usable Battery Energy Calculator?

The Usable Battery Energy Calculator has 4 main uses: realistic runtime, chemistry comparison, inverter selection and bank sizing.

  • Realistic runtime: Start runtime math from usable AC Wh, not the label Wh.
  • Chemistry comparison: Compare lead-acid and lithium batteries on usable energy.
  • Inverter selection: See how a 92% inverter delivers more than an 85% inverter.
  • Bank sizing: Work backward from usable Wh to the nominal size needed.

Usable Battery Energy Calculator FAQ

How much usable energy does a 100 Ah 12 V lead-acid battery give?▼

A 100 Ah 12 V lead-acid battery gives about 510–550 Wh to AC loads at 50% DoD.

What is depth of discharge?▼

Depth of discharge is the share of capacity used before recharging. 80% DoD leaves 20% in the battery.

Do DC loads have inverter losses?▼

No, DC loads skip the inverter. Use 100% inverter efficiency for them, minus any DC-DC converter loss.