Skip to main content
Watt Hour Calculator logo
Watt Hour Calculator

Battery Sizing and Runtime

Battery Round-Trip Efficiency Calculator

Compare final discharge output energy with initial recharge input to measure full round-trip efficiency.

Battery Round-Trip Efficiency Calculator InputsRTE (%) = kWh(out) ÷ kWh(in) × 100
kWh
kWh
Result
Round-trip efficiency
90%
Energy lost1 kWh
Loss per 100 kWh cycled10 kWh
Step-by-step working▼
  1. RTE = 9 ÷ 10 × 100 = 90%
  2. Loss = 10 − 9 = 1 kWh

What Is the Battery Round-Trip Efficiency Calculator?

A Battery Round-Trip Efficiency Calculator is a tool that divides the energy discharged from a battery by the energy charged into it to give round-trip efficiency (RTE) as a percentage.

Round-trip efficiency covers both charging and discharging losses. A home battery that takes 10 kWh in and gives 9 kWh out has an RTE of 90%. Every 100 kWh cycled through the battery loses 10 kWh.

The calculator returns RTE, energy lost and the loss per 100 kWh cycled.

How Does the Battery Round-Trip Efficiency Calculator Work?

The Battery Round-Trip Efficiency Calculator works by dividing discharged kWh by charged kWh and multiplying by 100.

  1. Read the energy charged: Take the kWh charged in from the inverter app or a meter.
  2. Read the energy discharged: Take the kWh delivered over the same period, starting and ending at the same SoC.
  3. Enter both values: Type the charged and discharged kWh.
  4. Read the RTE: The tool shows RTE and losses.

Battery Round-Trip Efficiency Calculator Formula

The Battery Round-Trip Efficiency formula is RTE = kWh(out) ÷ kWh(in) × 100.

RTE (%) = kWh(out) ÷ kWh(in) × 100

  • RTE = η(charge) × η(discharge)
  • Loss = kWh(in) − kWh(out)
Variables in the Battery Round-Trip Efficiency Calculator formula
SymbolMeaning
RTERound-trip efficiency
kWh(in)Energy charged in
kWh(out)Energy discharged out
ηOne-way efficiency

Battery Round-Trip Efficiency Calculator Example

Over a month, a home battery charged 312 kWh and discharged 278 kWh, starting and ending at 50% SoC.

  1. RTE = 278 ÷ 312 × 100
  2. RTE = 89.1%
  3. Loss = 312 − 278 = 34 kWh

The battery has a round-trip efficiency of 89.1%.

Battery Round-Trip Efficiency Calculator Conversion Table

The table lists typical RTE values for 6 storage types.

Round-trip efficiency by storage type
Storage typeTypical RTEOut per 10 kWh inLoss per 10 kWh
LiFePO4 home battery (AC-coupled)89–92%9.0 kWh1.0 kWh
LiFePO4 (DC-coupled)94–96%9.5 kWh0.5 kWh
Li-ion NMC90–95%9.2 kWh0.8 kWh
Lead-acid75–85%8.0 kWh2.0 kWh
Flow battery65–80%7.3 kWh2.7 kWh
Pumped hydro70–85%7.8 kWh2.2 kWh

AC-coupled batteries convert twice (AC to DC and back), so their RTE is lower than DC-coupled systems.

What Are the Uses of the Battery Round-Trip Efficiency Calculator?

The Battery Round-Trip Efficiency Calculator has 4 main uses: battery comparison, time-of-use savings, warranty checks and storage economics.

  • Battery comparison: Compare RTE figures across brands and chemistries.
  • Time-of-use savings: Check that the price gap beats the RTE loss.
  • Warranty checks: Compare measured RTE with the datasheet figure.
  • Storage economics: Include RTE losses in the cost per stored kWh.

Battery Round-Trip Efficiency Calculator FAQ

What is a good round-trip efficiency?▼

A good round-trip efficiency is 90% or higher for a lithium home battery.

Does round-trip efficiency include inverter losses?▼

Yes, AC-to-AC RTE includes the inverter in both directions.

Why start and end at the same SoC?▼

Equal start and end SoC keeps stored energy out of the result, so only losses remain.